Specifications
| Part number | 38OT022P00004 |
|---|
| Brand / catalogue | OTIS / VARIOUS |
|---|
| Part family | Frequency drive |
|---|
| Subassembly | Control and electronics |
|---|
| Rated load | 1000 kg |
|---|
| Part numbers cited | OVFR03-B, GDA21305KY6, GCA26800PS2, KDA26800ABS6 |
|---|
| Type of supply | As per supplier catalogue |
|---|
| Availability | To be confirmed on quotation |
|---|
About this part
KMY lists “VARIATEUR Ultra drive OVFR03-B GDA21305KY6 pour 1000 kg - Avec carte GCA26800PS2 - Remplace KDA26800ABS6” under code 38OT022P00004, in its OTIS / VARIOUS range.
The supplier description indicates a load of 1000 kg.
The frequency drive supplies the motor at variable voltage and frequency.
The description indicates that this part number replaces KDA26800ABS6: check that the substitution applies to your generation of equipment.
Manufacturer codes cited in the description: OVFR03-B, GDA21305KY6, GCA26800PS2, KDA26800ABS6. They make it easier to match the part currently fitted.
For a quote, give the part number 38OT022P00004, the make and model of your elevator and your wilaya: KMY confirms the final price, availability and delivery time in Algeria.
Points to check before ordering
- The communication mode with the controller (contacts, serial link), and full re-entry of the motor parameters after replacement.
- The power and rated current, to be checked against the motor nameplate — current is the deciding criterion, not just the stated power.
- The voltage and type of mains supply.
To understand the role of this component and the selection criteria in detail, see the page Frequency drives and associated boards.