05 60 06 16 54 WhatsApp Email
Elevator modernisation assessment, Algeria, KMY                                                    

Opening hours

08:00 - 16:00

Phone

05 60 06 16 54

Email

contact@groupekmy.com

A part to replace on your elevator?

Find the right part number for your installation in our multi-brand parts catalogue. Add your parts to a quote request; our team confirms compatibility, the final price and lead times.

Indicative prices in dinars, taxes included · Final quote and lead times on request.

Elevator modernisation assessment, Algeria, KMY

In November 2025, KMY Ascenseurs was commissioned by the building manager to carry out an in-depth technical assessment of the 4 THYSSENKRUPP elevators installed in an office tower in Les Pins Maritimes, Algiers. These installations, more than twenty years old, were suffering recurrent breakdowns and advanced wear.

1. The challenge of 2000s Thyssenkrupp elevators in Algeria

THYSSENKRUPP elevators of this generation feature a tightly integrated quadruplex system, proprietary automation that is hard to maintain, extremely sensitive glass encoders and CPU boards that are now almost impossible to find. In 2025, spare parts prices were rising by 12 to 18% a year, and lead times were getting longer.

This situation is typical of many Algerian buildings equipped in the 2000s with high-end European brands: the elevators ran well for 15 to 20 years but are now reaching the end of their technical life.

2. Elevator L01: encoder failure and misaligned guides

When our teams arrived, elevator L01 was completely out of service. Tests in inspection mode revealed no correct feedback from the motor to the controller, violent vibrations from the first pulses and irregular braking. Diagnosis: failure of the original glass encoder, a technology abandoned by manufacturers because it is extremely sensitive to vibration and its fragile disc causes reading losses at the end of its life.

Recommended solution: replacement with a WDG100H38 incremental encoder (4,096 pulses), mechanically and electronically compatible with the period CPI/MCI drives and offering a much longer service life.

In addition, significant misalignment of the car and counterweight guides was detected — a risk of lateral rubbing, accelerated shoe wear and failure at a statutory inspection. A complete mechanical correction of the guiding was prescribed.

3. Elevator L02: central CPU failure

Elevator L02 did not respond to any command, in normal service or in inspection mode. There was no communication at all between the CPU and the input/output modules, the drive was locked and the landing network partly inactive. Diagnosis: complete failure of the MCI-E CPU board (reference 747) — an extremely rare component that is no longer produced.

Solution: replacement with an MCI-E V3 CPU kit, compatible with the original architecture, offering better signal stability and improved control of the CPI drive.

4. Elevators L03 and L04: working but at the end of their cycle

These two elevators were still in service but showed clear signs of ageing: vibration during deceleration, slightly abrupt stops at some floors, fatigued CPI/MFC48 drives and mechanical play in the governor. Preventive work was planned in the medium term to avoid a major breakdown.

5. A recommended 3-phase strategic plan

Phase 1 — Immediate return to service: replace the L01 encoder, replace the L02 CPU, correct the guides mechanically, check the landing line. Goal: quickly restore vertical transport for the building's many users.

Phase 2 — Stabilising L03 and L04: replace the TMI2 computer if necessary, check the governor, overhaul the CPI drive, full interference suppression. Goal: prevent a major breakdown on the elevators still in service.

Phase 3 — Gradual renovation: renovate one elevator a year to spread the investment, salvage parts that are still usable and anticipate the growing scarcity of components. This approach avoids taking all four elevators out of service at once.

6. A lesson for building managers in Algeria

An elevator more than 15 years old needs a complete assessment by an independent technician, even if it still seems to work. Major breakdowns in ageing fleets rarely occur in isolation: they usually signal overall ageing of the fleet. Planning ahead with a gradual renovation plan is always cheaper than an emergency shutdown. KMY Ascenseurs offers this type of assessment for any elevator fleet in Algeria.

Kaidi Yacine, founder of KMY Ascenseurs Algeria

Y. Kaidi

My dual technical and commercial expertise, built through substantial field experience, allows me to provide innovative solutions tailored to clients' needs.

Free quote

Get your quote in a few clicks

Configure your elevator and download your technical data sheet + estimate as a PDF.